Skip Navigation

NVRI Publications

NVRI Publications

If you would like a copy of any NVRI publications please email your request to admin@nvri.org.au and we will be pleased to send them to you ASAP.

NVRI publications

2016

Neurotechnology

  1. Ahnood A, Simonov AN, Laird JS, Maturana MI, Ganesan K, Stacy A, Ibbotson MR, Spiccia L, Prawer S (2016). Transient photoresponse of nitrogen-doped ultrananocrystalline diamond electrodes in saline solution. Applied Physics Letters (submitted 17 December, accepted 18 January, 2015).
  2. Kameneva T, Maturana MI, Hadjinicolaou AE, Cloherty S, Ibbotson MR, Grayden DB, Burkitt AN, Meffin H (2016). Retinal ganglion cells: mechanisms underlying depolarization block and differential responses to high-frequency electrical stimulation of ON and OFF cells. J Neural Eng. 13:1 (accepted 23 November, 2015).
  3. Maturana MI, Apollo NV, Hadjinicolaou AE, Garrett DJ, Cloherty SL, Kameneva T, Grayden DB, Ibbotson MR, Meffin H (2016). A simple and accurate model to predict responses to multi-electrode stimulation in the retina. PLoS Computational Biology. (Accepted, 11 March 2016).
  4. ClohertySL, Hughes NJ, Hietanen MA, Bhagavatula P, Goodhill GJ, Ibbotson MR (2016). Orientation pinwheels in visual cortex can be repositioned by sensory experience. eLife (Accepted 13 May, 2016).
  5. Wong YT, Halupuka K, Kameneva T, Cloherty SL, Grayden DB, Burkitt AN,Meffin H, Shivdasani MN (2016) Spectral distribution of local field potential responses to electrical stimulation of the retina. J. Neural Eng. 13(2), Art #036003
  6. Garrett DJ, Tong w, Simpson D, Meffin H (2016) Diamond for neural interfacing: A review. Carbon 102: 437-454
  7. Garret DJ, Saunders AL, McGowan C, Specks J, Ganesan K, Meffin H, Williams RA, Nayagam DAX (2016) In vivo biocompatibility of boron doped and nitrogen incuded conductive-diamond for use in medical implants. J.Biomed. Materials Res. B: Appl. Biomaterials. 104(1): 19-26
  8. Apollo NV, Lau D, Ahnod A, Ganesan K, Lichter SG, Fox K, Forughi J, Meffin H, Wallace GG, Baughman R, Prawer S, Garret DJ (2016) Brazing techniques for the farication of biocompatible carbon based electronic devices. Carbon (in press)

Clinical Research 

  1. Bentley SA, Cartledge A, Guest DJ, Cappucio S, Woods CA (2016). Practitioner perspectives on extended clinical placement programs in optometry. Clin Exp Optom 99:248-257
  2. Fenwick EK, O’Hare F, Deverell L, Ayton LN, Luu CD, McSweeney S, Bentley SA, Guymer RH, Finger RP (2016). Rasch analysis of the independent mobility questionnaire. Optometry & Vision Science 93: 181-187
  3. Muir C, Charlton J, Keefe J, Wood J, Bohensky M, Fildes B, Oxley J, Bentley S, Rizzo M (2016) Medical review licencing outcomes in drivers with visual fields loss. Clin Exp Optom (in press)
  4. Finger RP, Ayton LN, Deverell L, O’Hare F, McSweeney SC, Luu CD, Fenwick EK, Keefe JE, Guymer RH, Bentley SA (2016) Developing a very low vision orientation and mobility test battery (O&M-VLV) Optometry and Vision Sciences (in press)
  5. Woods C, Bentley S, Fonn D. (2016) Temporal changes in contact lens comfort over a day of wear. Ophthalmic and Physiological Optics (accepted July 2016)

Non-Peer Reviewed

  1. Lombardi L, Bruce AS (2016) Glaucoma without Cupping. Case Report: Optometry Australia Pharma March 2016

 

2015

Neurotechnology

  1. Hadjinicolaou AE, Savage CO, Garrett DJ, Apollo NV, Cloherty SL, Ibbotson MR, O’Brien BJ (2015). Optimal electrical stimulation of retinal ganglion cells. Trans Neural Syst Rehabil Eng, 23: 169-178. PMID: 25343761.
  2. Cloherty SL, Ibbotson MR (2015). Contrast-dependent phase sensitivity in V1 but not V2 of macaque visual cortex. J Neurophysiology 113: 434-444. PMID: 25355960.
  3. Apollo NV, Maturana M, Tong W, Zamani A, Turnley A, Foroughi J, Wallace G, Prawer S, Ibbotson MR, Garrett D (2015). Soft, Flexible Freestanding Neural Stimulation Electrodes Fabricated from Reduced Graphene Oxide. Advanced Functional Materials 25: 3551-3559.
  4. Stronks HC, Nau AC, Ibbotson MR, Barnes N (2015). The role of visual deprivation and experience on the performance of sensory substitution devices. Brain Research 1624: 140-152. PMID: 26183014.
  5. Maturana MI, Apollo N, Garrett DJ, Kameneva T, Meffin H, Ibbotson MR, Cloherty SL, Grayden DB (2015). The effects of temperature changes on retinal ganglion responses to electrical stimulation. IEEE Eng Med Biol Soc 2015: 7506-7509. PMID: 26738028.
  6. Hadjinicolaou AE, Meffin H, Maturana MI, Cloherty SL, Ibbotson MR (2015). Prosthetic vision: devices, patient outcomes and retinal research. Clin Exp Optom 98: 395–410. PMID: 26390902. 
  7. Cloherty SL, Crowder NA, Mustari MJ, Ibbotson MR (2015). Saccade-induced image motion cannot account for post-saccadic enhancement of visual processing in primate MST. Frontiers in Systems Neuroscience (01 Sept.) 9: 122. http://dx.doi.org/10.3389/fnsys.2015.00122.PMID: 26388747.
  8. Meffin H, Hietanen MA, Cloherty SL, Ibbotson MR (2015). Contrast dependence of spatial receptive field structure in primary visual cortex. J Neurophysiol. 114: 3326-3338. PMID 26378205.
  9. Hietanen MA, Cloherty SL, Ibbotson MR (2015). Contrast adaptation is dependent on visual cortical map location. European J Neurosci. October 2. doi: 10.1111/ejn.13091 [Epub ahead of print]. PMID: 26432621.
  10. Gavrilescu M, Battista J, Ibbotson MR, Gibbs P (2015). Visual fatigue induced by optical misalignment in binocular devices: application to night vision binocular devices. In: Display technologies and applications for defense, security, and avionics IX; and head- and helmet-mounted displays XX (eds: Desjardins DD, Marasco PL, Sarma KR, Havig PR, Browne MP, Melzer JE). Book Series: Proceedings of SPIE, 9470: 947010.
  11. Hietanen MA (2015). The relative contributions of global and local acceleration components on speed perception and discriminability following adaptation. Vision Research (accepted 23 June, 2015).
  12. Fox K., Garrett D.J., Burns O., Shivdasani M.N., and Meffin H., (2015) The bionic eye: review of multielectrode arrays, In Handbook of Bioelectronics, Cambridge Uni. Press, pp 294-312.
  13. Garrett D.J.,Tong W., Simpson D., Meffin H. (2016), Diamond for neural interfacing: A review, Carbon, Accepted 22/02/2016.
  14. Garrett D.J., Saunders A.L., McGowan C., Specks J., Ganesan K., Meffin H., Williams R.A., Nayagam D.A.X  (2016), In vivo biocompatibility of boron doped and nitrogen included conductive‐diamond for use in medical implants, J. Biomed. Materials Res.  B: Appl. Biomaterials, 104(1): 19-26.
  15. Fox K., Meffin H., Burns O., Abbott C.J., Allen P.J., Opie N.L., McGowan C., Yeoh J., Ahnood A.,  Luu C.D., Saunders A.L., McPhedran M., Cardamone L.,Villalobos J., Garrett D.J., Nayagam D.A.X., Apollo N., Ganesan K., Stacey A., Escudie M., Lichter S., Shepherd R.K., Prawer S., (2015) Development of a magnetic attachment method for bionic eye applications,  Artificial Organs, Epub ahead of print doi: 10.1111/aor.12582.
  16. Ahnood A., Escudie M.C.,Cicione R., Abeyrathne C.D., Ganesan K., Fox K.E., Garrett D.J., Stacey A.,  Apollo N.V.,  Lichter S.G., Thomas C.D.L., Tran N., Meffin H., Prawer S., (2015) Ultrananocrystalline diamond-CMOS device integration route for high acuity retinal prostheses, Biomedical Microdevices, 17(3): 1-11.
  17. Spencer M.J., Naygam D.A.X., Clarey J.C., Paolini A.G., Meffin H., Burkitt A.N., Grayden D.B., (2015) Broadband onset inhibition can suppress spectral splatter in the auditory brainstem, PLoS One, 10(5), Art# e0126500.
  18. Lichter S.G., Escudie M.C., Stacey A.D., Ganesan K., Fox K., Ahnood A., Apollo N.V., Kua D.C.,1,3 Lee A.Z., McGowan C., L. Saunders A.L., Burns O., Nayagam D.A.X. , Williams R.A,  Garrett D.J., Meffin H., Prawer S. (2015)  Hermetic diamond capsules for biomedical implants enabled by gold active braze alloys, Biomaterials 53: 464-474.
  19. Kameneva T., Abramian M., Zarelli D., Nesic D., Grayden D.B., Burkitt A.N. Meffin H., (2015) Spike history neural response model, J. Comput. Neurosci. 38(3): 463-481.

Clinical Research 

  1. Tapp R, Svoboda J, Fredericks B, Jackson AJ, Taylor HR (2015). Retinal Photography Screening Programs to Prevent Vision Loss from Diabetic Retinopathy in Rural and Urban Australia: A Review. Ophthalmic Epidemiology 22: 52-59.
  2. Ayton L, Bentley S, Guymer R (2015). How to Treat: Low Vision. Australian Doctor. 24 April 2015: 21-28.
  3. Li J, Wong K, Park A, Fricke TR, Jackson AJ (2015). The challenges of providing eye care for adults with intellectual disabilities. Clin Exp Optom 98(5): 420-429.
  4. O’Hare F, Bentley SA, Wu Z, Guymer RH, Luu CD, Ayton LN (2015). Charles Bonnet Syndrome in Advanced Retinitis Pigmentosa. Ophthalmology 122: 1951-1953.
  5. Deverell E, Bentley SA, Ayton LN, Delany C, Keeffe JE (2015). Effective Mobility Framework: A Tool for Designing Comprehensive O&M Outcomes Research. International Journal of Orientation and Mobility. 7(1)
  6. Nixon P, Li J, Baker RJ, Dash A, Jackson AJ, Fricke T (2015). Barriers to vision correction for children in a disadvantaged school community. Clin Exp Optom. 16(3): 85-94
  7. Napper G, Fricke T, Anjou MD, Jackson AJ. (2015) Breaking Down Barriers to Eye Care for Indigenous People: A New Scheme for Delivery of Eye Care in Victoria. Clin Exp Optom. 98(5): 430-434

Non-Peer Reviewed

  1. Campbell J, Bruce AS (2015). When Bigger is Better: For Patients Who Cannot Tolerate GP Lenses. Australian Optometry News. May: Pg9
  2. Ng HW, Bruce AS (2015). Prosthetic Contact Lenses in the Hospital Environment. Australian Optometry News. May: Pg10

 

2014

Neurotechnology

  1. Bhagavatula PS, Claudianos C, Ibbotson MR, Srinivasan MV (2014). Behavioural lateralization and optimal route choice in flying budgerigars. PLoS Comput Biol 10(3): e1003473. PMID: 24603285
  2. Hung Y-S, Ibbotson MR (2014). Ocellar structure and neural innervation in the honeybee. Front Neuroanat 8: 6: 1-11. PMID: 24600354
  3. Hughes N, Hunt JJ, Cloherty SL, Ibbotson MR, Sengpield F, Goodhill GJ (2014). Stripe-rearing changes multiple aspects of the structure of primary visual cortex. Neuroimage 95: 305-319. PMID: 24657308
  4. Wong RCS, Garret D, Grayden D, Ibbotson MR, Cloherty SL (2014). Efficacy of electrical stimulation of retinal ganglion cells with temporal patterns resembling light-evoked spike trains. IEEE Eng Med Biol Soc 2014. 1707-1710. PMID: 25570304
  5. Maturana MI, Kameneva T, Burkitt AN, Meffin H, Grayden DB. (2014). The effect of morphology upon electrophysiological responses of retinal ganglion cells: simulation results. J Comput Neurosci 36: 157–175.
  6. Battista J, Ibbotson MR (2014). Sensitivity of FIT optometric parameters to binocular misalignment. DSTO technical report.

Clinical Research

  1. Healey N, McClelland J, Saunders K, Jackson J (2014). Longitudinal Study of Spherical Refractive Errors in Infantile Nystagmus Syndrome. Ophthalmic and Physiological Optics 34: 369-375.
  2. Bentley S, Jackson J, Johnston A, Napper G, Hodgson M, Soong G, Oberstein S, Chong M, Baggoley G (2014). Advancing Low Vision Services: A Plan for Australian Optometry. Clin Exp Optom 97: 214-220.
  3. Wolffsohn JS, Jackson J, Hunt O, Cottriall C, Lindsay J, Gilmour R, Sinclair A, Harper R    (2014). An Enhanced Functional Ability Questionnaire (faVIQ) to Measure the Impact of Rehabilitation Services on the Visually Impaired. International Journal of Ophthalmology. 7(1): 77–85.
  4. Bentley S, Jackson J (2014). Editorial: Will optometry respond to the growing challenge of providing evidence-based low vision care? Clin Exp Optom 97: 193-195.
  5. Bruce AS (2014). Re: Silicone hydrogel mini-scleral contact lenses in early stage after corneal collagen cross-linking for keratoconus: a retrospective case series. Clin Exp Optom 97: 280.
  6. Truong M, Bentley S, Napper GA, Guest DJ, Anjou MD (2014). How Australian And New Zealand Optometry Schools Prepare Optometry Students For Culturally Competent Practice. Clin Exp Optom 97: 540-549.
  7. Bruce A, Catania L J (2014). Clinical Applications of Wavefront Refraction. Optometry Vision Science 91:1278-1286.
  8. Finger RP, McSweeney SC, Deverell L, O’Hare F, Bentley SA, Luu CD, Guymer RH, Ayton N (2014). Developing An Instrumental Activities of Daily Living Tool as part of the Low Vision Assessment of Daily Activities protocol. Invest. Ophthalmol. Vis. Sci. 55: 8458-8466.

Non-Peer Reviewed

  1. Binns A, Bentley SA (2014). Age-Related Macular Degeneration: Optometrist’s Role In Detection And Management (Review). Optometry in Practice 15: 151-160.
  2. Bruce A, Huang I (2014). Fundus Photography in a New Light Australian Optometry. Australian Optometry (Pharma) March, pages 8-9.
  3. Serebrianik R (2014). Fundus Autofluorescence: RPE – But Not As You Know It, Optometrists Association Australia, Equipment Supplement (April 2014) Pg19-21

 

2013

Neurotechnology

  1. Hung Y-S, Van Kleef JP, Stange G, Ibbotson MR (2013). Spectral inputs and ocellar contributions to a pitch-sensitive descending neuron in the honeybee. J Neurophysiol. 109: 1202–1213. This paper forms the basis of the cover art on the February issue of the journal. PMID: 23197452
  2. Hietanen MA, Cloherty SL, van Kleef JP, Wang C, Dreher B, Ibbotson MR(2013). Phase-sensitivity of complex cells in primary visual cortex. Neuroscience 237: 19–28. PMID: 23357120
  3. Maturana M, Wong RCS, Cloherty SL, Ibbotson MR, Hadjinicolaou AE, Grayden DB, Burkitt AN, Meffin H, O’Brien BJ, Kameneva T (2013). Retinal ganglion cell electrophysiology: the effect of cell morphology on impulse waveform. IEEE Eng Med Biol Soc 2013: 2583-2586. PMID: 24110255
  4. Baird E, Böddeker N, Ibbotson MR, Srinivasan MV (2013). How honeybees land on vertical surfaces: a universal strategy for visually-guided landing. Proc Natl Ac Sci 110: 18686-18691. PMID: 24167269 IF=9.81
  5. Maturana MI, Grayden DB, Burkitt AN, Meffin H, Kameneva T (2013). Multicompartment retinal ganglion cells response to high frequency bi-phasic pulse train stimulation: Simulation results. IEEE Eng Med Biol. 2013: 69-72.
  6. McKendrick AM, Weymouth AE, Battista J (2013)  Visual form perception from age 20 through 80 years. Invest Ophthalmol Vis Sci. 54: 1730-1739.
  7. McKendrick AM, Battista J (2013). Perceptual learning of contour integration is not compromised in the elderly. J Vision 13: 5.
  8. Morris AP, Bremmer F, & Krekelberg B (2013) Eye-position signals in the dorsal visual system are accurate and precise on short timescales. Journal of Neuroscience, 33: 12395-12406.
  9. Guez, J, Morris AP, Krekelberg B (2013). Intrasaccadic suppression is dominated by reduced detector gain. J Vision 13: 4, 1-11.

Clinical Research  

  1. Bailey IL, Jackson AJ, Minto H, Greer RB, Chu MA (2013). The Berkeley Rudimentary Vision Test (BRVT) – Authors Response. Optometry Vision Science 90: e39-40.
  2. Bailie M, Wolffsohn JS, Stevenson M, Jackson AJ (2013). Functional and perceived benefits of wearing coloured filters by patients with age-related macular degeneration. Clin Exp Optom 96: 450-454.
  3. Bruce AS (2013). Book review – Contact Lens Complications. Clin Exp Optom 96: 359.
  4. Bruce AS, Nguyen LM (2013). Acute Red Eye (Non-Ulcerative Keratitis) Associated With Mini-Scleral Contact Lens Wear For Keratoconus, Clin Exp Optom 96: 245-248.
  5. Carozzi PN (2013). Eyecare for Homeless People: Ten Years On. Clin Exp Optom 96: 441-442.
  6. Little JA, McCullough S, McClelland J, Jackson AJ, Saunders KJ (2013). Low-Contrast Acuity Measurement: Does It Add Value in the Visual Assessment of Down Syndrome and Cerebral Palsy Populations. Invest Ophthalmol Vis Sci 54: 251-257.
  7. Napper GA, Sorraghan J, Wood J, Crerie G, Moise A (2013). Why Optometry Must Work from Urban and Regional Aboriginal Health Services. Clin Exp Optom 96: 249-250.
  8. Natasha Healey, Eibhlin McLoone, Gerald Mahon, A Jonathan Jackson, Kathryn J Saunders, Julie F McClelland (2013). Is Impaired Emmetropisation Related to Foveal Hypoplasia or Is It Specific to Albinism? – Authors’ Response. Invest Ophthalmol Vis Sci 54: 4006.
  9. Tahhan N, Papas E, Fricke TR, Frick KD, Holden BA (2013). Utility And Uncorrected Refractive Error. Ophthalmology 120: 1736-1744.

Non-Peer Reviewed

  1. Serebrianik R (2013). OCT: Look Beyond the Macula and Optic Nerve. Australian Optometry (Pharma) June, pages 12-14.
  2. Serebrianik R (2013). Fundus Photography in a New Light. Australian Optometry (Pharma) December, pages 13-15.
  3. Hall A (2013). Risk Factors Call For Multidisciplinary Management Of Central Serous Retinopathy. Australian Optometry (Pharma) June, pages 26-27.
  4. Chong MFA, Jackson AJ (2013). Low Vision: More than Just Magnifiers. My Vision 86: 53-57.
  5. Huang I, Jackson AJ (2013). Common Optical Devices and Assistive Technology, Australian Optometry (Pharma) September, pages 39-42.
  6. Li JCH, Dacion L, Jackson AJ (2013). Targeted Eyecare Service for People Experiencing Homelessness. Parity (Council to Homeless Persons’ National Publication) 26:1 42-43.

 

2012

Neurotechnology

  1. Hadjinicolaou AE, LeungRT, Garrett DJ, Ganesan K, Fox K, Nayagam DAX, Shivdasani MN, Meffin H, Ibbotson MR, Prawer S, O’Brien BJ (2012). Electrical stimulation of retinal ganglion cells with diamond and the development of an all diamond retinal prosthesis. Biomaterials 33: 5812–5820. PMID: 22613134
  2. Hunt J, Ibbotson MR, Goodhill G (2012). Sparse coding on the spot: spontaneous retinal waves suffice for orientation selectivity. Neural Computation 24: 2422-2433. PMID: 22734490
  3. Ibbotson MR (2012). Bionic eyes – where are we and what does the future hold? Clinical Exp. Optom. 95: 471-472. PMID: 22925014
  4. Cloherty SL, Wong RCS, Hadjinicolaou AE, Meffin H, Ibbotson MR, J. O'Brien BJ (2012). Epiretinal Electrical Stimulation and the Inner Limiting Membrane in Rat Retina. IEEE Eng Med Biol Soc 2012: 2989-2992. PMID: 23366553
  5. Wong RCS, Cloherty SL, Ibbotson MR, O'Brien BJ (2012). Intrinsic physiological properties of rat retinal ganglion cells with a comparative analysis. J. Neurophysiol. 108: 2008-2023. PMID: 22786958

Clinical Research 

  1. Williams, ED, Rawal, L, Oldenburg, BF, Renwick, C, Shaw, JE, Tapp, RJ (2012). Risk of Cardiovascular and All-Cause Mortality: Impact of Impaired Health-Related Functioning and Diabetes The Australian Diabetes, Obesity and Lifestyle (AusDiab) study. Diabetes Care 35: 1067-73.
  2. Conway, M, Hosking SL (2013). Investigation of Ocular Hemodynamics in Sturge-Weber Syndrome. Opt Vis Sci 89: 922-928.
  3. Bruce AS (2012). Using Imaging for Education and Clinical Excellence. Optometry Vision Science 89 (10): e28.
  4. Binns AM, Bunce C, Dickinson C, Harper R, Tutor-Edwards R Woodhouse M, Linck P, Suttie A, Jackson AJ,Lindsay J, Wolffsohn J, Hughes L, Morgrain TH (2012). How Effective is Low Vision Service Provision. A Systematic Review. Surv Ophthalmol 57 (1): 34-65.
  5. Cupples ME, Hart PM, Johnston A, Jackson AJ (2012). Improving Healthcare Access for People with Visual Impairment and Blindness. Brit Med J 30: 344 e542.
  6. Bailey IL, Jackson AJ,Minto H, Greer RB, Chu MA (2012). The Berkeley Rudimentary Vision Test (BRVT). Optom Vis Sci 87(9): 1257-1264.
  7. Chung STL, Bailey IL, Dagnelie G, Jackson AJ,Legge GE, Rubin GS, Wood J (2012). New Challenges in Low Vision Research. Optom Vis Sci 89(9): 1244-1245.
  8. McCann RM, Jackson AJ, Stevenson MR, Dempster M, McEnlay JC, Cupples ME (2012). Help needed in Medication Self Management for People with Vision Impairment: Case Control Study. Brit J Gen Pract 62: 601 e530-537.
  9. Napper GA, Truong M, Anjou MD (2012). Editorial - There are people in Australia who have poor vision or eye disease that is avoidable - what more can we do? Clin Exp Optom 95(6): 569-571.
  10. Weymouth AE,AM McKendrick (2012). Shape Perception Is Altered By Normal Aging. Invest Ophthalmol Vis Sci (2012) 53(6): 3226-3233.
  11. Chan YM, Battista J, McKendrick AM (2012). Aging effects on collinear facilitation. J Vis 12: 21. 
  12. Webster KE, Dickinson JE, Battista J, McKendrick AM, Badcock DR (2012). Evidence for increased internal noise in migraineurs for contrast and shape processing. Cephalalgia 32: 125-139. 

Non-Peer Reviewed

  1. McCann R, Jackson AJ (2012). Medication Handling And The Elderly Patient: A Challenge For The Optometrist. Optometry in Practice 13(2): 55-64.
  2. Fricke TR, Holden BA, Wilson DA, Schlenther G, Naidoo KS, Resnikoff S, Frick KD (2012). Global Cost of Correcting Vision Impairment from Uncorrected Refractive Error. Bull World Health Org 90(10): 728-738.
  3. Jackson AJ, Edgar DT (2012). Editorial Review – Vision and Ageing. Optometry in Practice 13 (2) ii-iv.
  4. Gallagher BA, Jackson AJ (2012). Ageing And The Impact Of Vision Loss On Independent Living And Mobility. Optometry in Practice 13(2): 45-54.

 

2011 (from July)

Neurotechnology

  1. Ibbotson MR, Krekelberg B (2011). Visual perception and saccadic eye movements. Current Opinion in Neurobiology 21: 553–558. PMID: 21646014
  2. Bhagavatula P, Claudianos C, Ibbotson MR, Srinivasan MV (2011). Optic flow cues guide flight in birds. Current Biology 21: 1794–1799. PMID: 22036184
  3. Hung Y-S, Van Kleef J, Ibbotson MR (2011). Visual response properties of neck motor neurons in the honeybee. J. Comp. Physiol. A.197: 1173-1187. PMID: 21909972
  4. Edwards M, Ibbotson MR (2011). Balancing act. Australasian Science 32: 26-28.

Clinical Research

  1. Napper GA (2011). "Curbside Consultation in Cornea and External Disease.  49 Clinical Questions", Clin Exp Optom 94:400.
  2. Bruce AS (2011). Anterior Eye Disease and Therapeutics A - Z (2nd edition). April 2011.

Non-Peer Reviewed

  1. Nguyen L M (2011). Normal Tension Glaucoma. Australian Optometry (Pharma) June 2011.